ICP / IEPE accelerometer module
Listens to your structure: directly powers and conditions ICP/IEPE piezo accelerometers for vibration analysis.
- Family code
- ICP
- Variants
- 4 / 8 / 12
- Power per module
- 4.6 W
- Record & replay
- RP option
What it acquires
ICP/IEPE sensors powered by the module itself: accelerometers, and other ICP-type sensors of dynamic pressure, force or strain. One delta-sigma converter per channel samples all channels simultaneously; acquisition runs continuously or on trigger, with pre- and post-trigger.
Typical uses
- Vibration analysis
- Structural dynamics
Key specifications
- Sampling
- Up to 62.5 kHz per channel, simultaneous
- Conversion
- 24-bit delta-sigma, 16 bits stored
- ICP current
- 1 to 5 mA, programmable
- Input ranges
- ±100 mV, ±1 V, ±5 V, ±10 V
Values from the module datasheet. Pinouts, drawings and full specifications: on request. Request the datasheet →
VARIANTS & PART NUMBERS
One reference per module
As the NanoX configurator composes them.
| Variant | Part number | With record & replay (RP) |
|---|---|---|
| 4 channels | ICP-4-NX | ICP-4-RP-NX |
| 8 channels | ICP-8-NX | ICP-8-RP-NX |
| 12 channels | ICP-12-NX | ICP-12-RP-NX |
- RP = record & replay: the RP version plays data recorded by the NanoX back on its outputs, from the stored files; depending on the family, it keeps its inputs as well or is dedicated to replay.
- Each module takes one of the NanoX's sixteen slots.
- Power per module: datasheet value, for the most demanding variant.
GO FURTHER
The articles that explain
Sensor conditioning: strain gauges, thermocouples, IEPE and LVDT
Everything upstream of the converter decides the ceiling. A guide to what each sensor family actually demands, and to the errors that survive all the way into the report.
Acquisition & recordingSampling, quantisation and aliasing: how not to record a false measurement
Most defects in a measurement chain announce themselves. Aliasing does not: it produces a clean, plausible, entirely fictitious signal, and it is the only error in the chain that cannot be repaired afterwards.
RELATED MODULES
In the same NanoX
The full datasheet, on request
Pinouts, connectors, drawings and full specifications: tell us which module, and our team sends the datasheet.
Request the datasheet →