Bridge signal module (piezoresistive)

For piezoresistive bridge sensors — force, pressure, acceleration — with built-in excitation.

Family code
BRIDGE
Variants
4 / 8 / 12
Power per module
4.6 W
Record & replay
RP option

What it acquires

Bridge sensors — piezoresistive force, pressure or acceleration sensors, or strain gauges — in full, half or quarter bridge, four-wire, with per-channel excitation from the module.

Typical uses

  • Force sensors
  • Pressure sensors
  • Accelerometers

Key specifications

Input ranges
±10 mV to ±10 V
Excitation
Up to ±12 V per channel, adjustable
Sampling
Up to 31 kHz or 250 kHz, depending on the version
Connector
Micro-D MIL-DTL-83513, 51 contacts

Values from the module datasheet. Pinouts, drawings and full specifications: on request. Request the datasheet →

VARIANTS & PART NUMBERS

One reference per module

As the NanoX configurator composes them.

Variant Part number With record & replay (RP)
4 channels · full or half bridge (FB) BRIDGE-FB-4-NX BRIDGE-FB-4-RP-NX
4 channels · quarter bridge (QB) BRIDGE-QB-4-NX BRIDGE-QB-4-RP-NX
8 channels · full or half bridge (FB) BRIDGE-FB-8-NX BRIDGE-FB-8-RP-NX
8 channels · quarter bridge (QB) BRIDGE-QB-8-NX BRIDGE-QB-8-RP-NX
12 channels · full or half bridge (FB) BRIDGE-FB-12-NX BRIDGE-FB-12-RP-NX
12 channels · quarter bridge (QB) BRIDGE-QB-12-NX BRIDGE-QB-12-RP-NX
  • RP = record & replay: the RP version plays data recorded by the NanoX back on its outputs, from the stored files; depending on the family, it keeps its inputs as well or is dedicated to replay.
  • FB = full or half bridge, QB = quarter bridge: the bridge completion, chosen in the configurator next to the channel count.
  • Each module takes one of the NanoX's sixteen slots.
  • Power per module: datasheet value, for the most demanding variant.

The full datasheet, on request

Pinouts, connectors, drawings and full specifications: tell us which module, and our team sends the datasheet.

Request the datasheet  →